Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
2.
Heart Rhythm ; 19(12): 1958-1964, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35781042

RESUMO

BACKGROUND: The absence of pacing capabilities may reduce the appeal of subcutaneous implantable cardioverter-defibrillator (S-ICD) devices for patients at risk for conduction disorders or with antitachycardia pacing (ATP)/cardiac resynchronization (CRT) requirements. Reports of rates of S-ICD to transvenous implantable cardioverter-defibrillator (TV-ICD) system switch in real-world scenarios are limited. OBJECTIVE: The purpose of this study was to investigate the need for a subsequent transvenous (TV) device in patients implanted with an S-ICD and its predictors. METHODS: All patients implanted with an S-ICD were enrolled from the multicenter, real-world iSUSI (International SUbcutaneouS Implantable cardioverter defibrillator) Registry. The need for a TV device and its clinical reason, and appropriate and inappropriate device therapies were assessed. Logistic regression with Firth penalization was used to assess the association between baseline and procedural characteristics and the overall need for a subsequent TV device. RESULTS: A total of 1509 patients were enrolled (age 50.8 ± 15.8 years; 76.9% male; 32.0% ischemic; left ventricular ejection fraction 38% [30%-60%]). Over 26.5 [13.4-42.9] months, 155 (10.3%) and 144 (9.3%) patients experienced appropriate and inappropriate device therapies, respectively. Forty-one patients (2.7%) required a TV device (13 bradycardia; 10 need for CRT; 10 inappropriate shocks). Body mass index (BMI) >30 kg/m2 and chronic kidney disease (CKD) were associated with need for a TV device (odds ratio [OR] 2.57 [1.37-4.81], P = .003; and OR 2.67 [1.29-5.54], P = .008, respectively). CONCLUSION: A low rate (2.7%) of conversion from S-ICD to a TV device was observed at follow-up, with need for antibradycardia pacing, ATP, or CRT being the main reasons. BMI >30 kg/m2 and CKD predicted all-cause need for a TV device.


Assuntos
Desfibriladores Implantáveis , Insuficiência Renal Crônica , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Volume Sistólico , Estudos Retrospectivos , Resultado do Tratamento , Função Ventricular Esquerda , Trifosfato de Adenosina
3.
Heart Rhythm ; 19(7): 1109-1115, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35257974

RESUMO

BACKGROUND: A few limited case series have shown that the subcutaneous implantable cardioverter-defibrillator (S-ICD) system is safe for teenagers and young adults, but a large-scale analysis currently is lacking. OBJECTIVES: The purpose of this study was to compare mid-term device-associated outcomes in a large real-world cohort of S-ICD patients, stratified by age at implantation. METHODS: Two propensity-matched cohorts of teenagers + young adults (≤30 years old) and adults (>30 years old) were retrieved from the ELISIR Registry. The primary outcome was the comparison of inappropriate shock rate. Complications, freedom from sustained ventricular arrhythmias, and overall and cardiovascular mortality were deemed secondary outcomes. RESULTS: Teenagers + young adults represented 11.0% of the entire cohort. Two propensity-matched groups of 161 patients each were used for the analysis. Median follow-up was 23.1 (13.2-40.5) months. In total, 15.2% patients experienced inappropriate shocks, and 9.3% device-related complications were observed, with no age-related differences in inappropriate shocks (16.1% vs 14.3%; P = .642) and complication rates (9.9% vs 8.7%; P = .701). At univariate analysis, young age was not associated with increased rates of inappropriate shocks (hazard ratio [HR] 1.204 [0.675-2.148]: P = .529). At multivariate analysis, use of the SMART Pass algorithm was associated with a strong reduction in inappropriate shocks (adjusted HR 0.292 [0.161-0.525]; P <.001), whereas arrhythmogenic right ventricular cardiomyopathy (ARVC) was associated with higher rates of inappropriate shocks (adjusted HR 2.380 [1.205-4.697]; P = .012). CONCLUSION: In a large multicenter registry of propensity-matched patients, use of the S-ICD in teenagers/young adults was safe and effective. The rates of inappropriate shocks and complications between cohorts were not significantly different. The only predictor of increased inappropriate shocks was a diagnosis of ARVC.


Assuntos
Displasia Arritmogênica Ventricular Direita , Desfibriladores Implantáveis , Adolescente , Adulto , Arritmias Cardíacas/diagnóstico , Displasia Arritmogênica Ventricular Direita/etiologia , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Sistema de Registros , Resultado do Tratamento , Adulto Jovem
4.
J Vasc Res ; 56(2): 92-96, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31079118

RESUMO

PURPOSE: Dronedarone is a multichannel-blocking antiarrhythmic drug for the treatment of atrial fibrillation. Observational data hypothesized a cardioprotective effect. In an in vitro endothelial cell-platelet model, we evaluated the molecular atheroprotective effects of dronedarone. METHODS: Following a 24-h incubation of human umbilical vein endothelial cells (HUVECs) with dronedarone (concentration 50, 100, and 150 ng/mL), they were then stimulated for 1 h with lipopolysaccharide (LPS) and were subsequently incubated in direct contact with thrombin-activated platelets. After incubation, the expression of CD40L and CD62P on platelets, and the expression of ICAM-1, VCAM-1, urokinase-type plasminogen activator receptor (uPAR), and membrane type 1 matrix metalloproteinase (MT1-MMP) on endothelial cells were measured by flow cytometry. RESULTS: Preincubation with 150 ng/mL of dronedarone reduced the expression of uPAR on endothelial cells after proinflammatory stimulation with LPS and also by direct endothelial contact with activated platelets (p = 0.0038). In contrast, the expression of CD40L and CD62P on platelets after proinflammatory stimulation with thrombin was significantly increased through direct preincubation with 50/100/150 ng/mL of dronedarone. However, dronedarone had no effects on the expression of MT1-MMP and ICAM-1 in HUVECs. CONCLUSION: In this in vitro analysis, dronedarone directly increased platelet activation but showed significant direct effects on endothelial cells and indirect effects on platelets on selected markers of atherosclerosis.


Assuntos
Aterosclerose/tratamento farmacológico , Plaquetas/efeitos dos fármacos , Fármacos Cardiovasculares/farmacologia , Dronedarona/farmacologia , Células Endoteliais da Veia Umbilical Humana/efeitos dos fármacos , Ativação Plaquetária/efeitos dos fármacos , Receptores de Ativador de Plasminogênio Tipo Uroquinase/metabolismo , Aterosclerose/metabolismo , Plaquetas/metabolismo , Ligante de CD40/metabolismo , Células Cultivadas , Citoproteção , Células Endoteliais da Veia Umbilical Humana/metabolismo , Humanos , Lipopolissacarídeos/farmacologia , Selectina-P/metabolismo , Transdução de Sinais
5.
BMC Cardiovasc Disord ; 18(1): 52, 2018 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-29544442

RESUMO

BACKGROUND: The wearable cardioverter-defibrillator (WCD) has emerged as a valuable tool to temporarily protect patients at risk for sudden cardiac death (SCD). The aim of this study was to determine the value of the WCD for therapy optimization of heart failure patients. METHODS: One hundred five consecutive patients that received WCD between 4/2012 and 9/2016 were included in the study. All patients were followed for clinical outcome and echocardiographic parameters during WCD therapy and had continued follow-up after WCD therapy, irrespective of subsequent implantable cardioverter-defibrillator (ICD) implantation. RESULTS: The most common indication for WCD were newly diagnosed ischemic (ICM) or non-ischemic cardiomyopathy (NICM) with left ventricular ejection fraction (LVEF) ≤35%. Mean WCD wear time was 68.8 ± 50.4 days with a mean daily use of 21.5 ± 3.5 h. Five patients (4.8%) received a total of five appropriate WCD shocks. During WCD wear, patients with ICM and NICM showed significant improvement in LVEF, reducing the proportion of patients with a need for primary preventive ICD implantation to 54.8% (ICM) and 48.8% (NICM). An ICD was finally implanted in 51.4% of the study patients (24 trans-venous ICDs, 30 subcutaneous ICDs). After discontinuation of WCD therapy, all patients were followed for a mean of 18.6 ± 12.3 months. 5.6% of patients with implanted ICDs received appropriate therapies. No patient with subcutaneous ICD needed change to a trans-venous device. None of the patients without an implanted ICD suffered from ventricular tachyarrhythmias and no patient died suddenly. In patients with NICM a significant LVEF improvement was observed during long-term follow-up (from 34.8 ± 11.1% to 41.0 ± 10.2%). CONCLUSIONS: WCD therapy successfully bridged all patients to either LVEF recovery or ICD implantation. Following WCD, ICD implantation could be avoided in almost half of the patients. In selected patients, prolongation of WCD therapy beyond 3 months might further prevent unnecessary ICD implantation. The WCD as an external monitoring system contributed important information to optimize device selection in patients that needed ICD implantation.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Adulto , Idoso , Tomada de Decisão Clínica , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Estudos Prospectivos , Implantação de Prótese/instrumentação , Recuperação de Função Fisiológica , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Procedimentos Desnecessários , Função Ventricular Esquerda
6.
Cardiovasc Revasc Med ; 17(8): 505-509, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27350417

RESUMO

BACKGROUND: Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. METHODS: The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose-area product (DAP) as well as the amount of contrast agent used were documented and analyzed. RESULTS: Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8min, p=0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p=0.826), procedural duration (46.0 vs. 45.0min, p=0.363) and contrast agent use (185.5 vs. 199.5ml, p=0.742) were also similar in radial and femoral PCI. CONCLUSION: There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI.


Assuntos
Cateterismo Periférico/métodos , Meios de Contraste/administração & dosagem , Doença da Artéria Coronariana/terapia , Artéria Femoral/diagnóstico por imagem , Iopamidol/análogos & derivados , Intervenção Coronária Percutânea/métodos , Artéria Radial/diagnóstico por imagem , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista , Idoso , Cateterismo Periférico/efeitos adversos , Meios de Contraste/efeitos adversos , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Fluoroscopia , Alemanha , Humanos , Iopamidol/administração & dosagem , Iopamidol/efeitos adversos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Valor Preditivo dos Testes , Estudos Prospectivos , Punções , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Interact Cardiovasc Thorac Surg ; 11(3): 366-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20515918

RESUMO

Pacemaker implantation after pneumonectomy is rare and there have been no previously reported cases of acquired dextrocardia after implantation. The authors report the case of a pacemaker implantation in a patient with complete heart block, impaired left ventricular function, sclerosis of heart valves and radiation induced vasculopathy resulting in ostial stenosis of the right coronary artery 30 years after radiochemotherapy in childhood. Acquired dextrocardia after right pneumonectomy for mucoepidermoid carcinoma made implantation a challenge due to and poor fluoroscopic visualization of the heart and increased radio-opacity of the right chest when compared to congenital dextrocardia.


Assuntos
Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial , Estenose Coronária/etiologia , Dextrocardia/etiologia , Pneumonectomia/efeitos adversos , Lesões por Radiação/etiologia , Escoliose/complicações , Tireoidectomia/efeitos adversos , Adulto , Antibióticos Antineoplásicos/efeitos adversos , Neoplasias Brônquicas/terapia , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/etiologia , Bloqueio de Ramo/fisiopatologia , Carcinoma Mucoepidermoide/terapia , Estenose Coronária/diagnóstico , Estenose Coronária/fisiopatologia , Dextrocardia/diagnóstico , Dextrocardia/fisiopatologia , Doxorrubicina/efeitos adversos , Eletrocardiografia , Desenho de Equipamento , Humanos , Imageamento por Ressonância Magnética , Masculino , Marca-Passo Artificial , Lesões por Radiação/diagnóstico , Lesões por Radiação/fisiopatologia , Resultado do Tratamento , Disfunção Ventricular Esquerda/etiologia , Função Ventricular Esquerda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA